Description of RED_HILLS-02.P (RED)

PestCast Network(s)

Lake County Grape, Lake County Pear and Grape

Observer

RACHEL ELKINS

Location

County: Lake    Nearest City: LAKEPORT
Latitude: 38 deg 55 min N    Longitude: 122 deg 44 min W    Elevation: 2002 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Grapes
Ground cover: Vineyard

Available data

UC IPM database records begin/end: March 20, 2002  /  on-going
Reporting interval: 15 minute, Hourly, Daily
Stored variables:
Air Temperature, max/min: HMP45C-L5 temp-rh probe
Air Temperature 2, max/min: 107-L30 thermistor
Air Temperature 3, max/min: 107-L700 thermistor
Air Temperature, average: HMP45C-L5 temp-rh probe
Air Temperature 2, average: 107-L30 thermistor
Air Temperature 3, average: 107-L700 thermistor
Chilling Hours: hours T < 45F
Dew Point Temperature: calculated from HMP45C temp-RH probe
Leaf wetness: 237-L30 resistance grid
Precipitation: TE525-L25 tipping bucket rain guage
Relative Humidity, max/min: HMP45C-L5 temp-rh probe
Relative Humidity, average: HMP45C-L5 temp-rh probe
Wind Sigma Theta: Calculated from 3001 RM Young Wind Sentry Anemometer and Vane
Solar Radiation: LiCor 200X Silicon pyranometer
Temperature Threshold Hours: hours of T <= 32F; 70 <= T <= 85F; T > 95F
Wind Speed/Direction, average: 3001 RM Young Wind Sentry Anemometer and Vane
Wind Speed/Direction, maximum: 3001 RM Young Wind Sentry Anemometer and Vane
Variables with computed averages: none


Details about reported variables

Air Temperature, max/min
Variable or Sensor: HMP45C-L5 temp-rh probe
Height of Sensor: 5 feet
Sensor Setup: outside grape canopy
When Installed: 22 March 2002
Averages Station Backup: LAKEPORT.C:AIR
Reporting Intervals: Daily, Hourly
Air Temperature 2, max/min
Variable or Sensor: 107-L30 thermistor
Height of Sensor: 4 feet
Sensor Setup: in grape canopy
When Installed: 10 April 1997
Averages Station Backup: LAKEPORT.C:AIR
Reporting Intervals: Daily, Hourly
Air Temperature 3, max/min
Variable or Sensor: 107-L700 thermistor
Height of Sensor: 4 feet
Sensor Setup: in grape canopy, 700' from station
When Installed: 10 April 1997
Averages Station Backup: LAKEPORT.C:AIR
Comment: Sensor is located in a gully at elevation of 1850 ft.
Reporting Intervals: Daily, Hourly
Air Temperature, average
Variable or Sensor: HMP45C-L5 temp-rh probe
Height of Sensor: 5 feet
Sensor Setup: outside grape canopy
When Installed: 22 March 2002
Reporting Intervals: Daily, Hourly, 15 minute
Air Temperature 2, average
Variable or Sensor: 107-L30 thermistor
Height of Sensor: 5 feet
Sensor Setup: in grape canopy
When Installed: 10 April 1997
Reporting Intervals: Daily, Hourly, 15 minute
Air Temperature 3, average
Variable or Sensor: 107-L700 thermistor
Height of Sensor: 4 feet
Sensor Setup: in grape canopy, 700' from station
When Installed: 10 April 1997
Reporting Intervals: Daily, Hourly, 15 minute
Chilling Hours
Variable or Sensor: hours T < 45F
Sensor Setup: in grape canopy
When Installed: 30 January 1998
Reporting Intervals: Daily
Dew Point Temperature
Variable or Sensor: calculated from HMP45C temp-RH probe
Sensor Setup: in grape canopy.
When Installed: 19 March 2002
Reporting Intervals: Daily, Hourly, 15 minute
Leaf wetness
Variable or Sensor: 237-L30 resistance grid
Height of Sensor: plant height
Sensor Setup: in grape canopy
When Installed: 15 May 1997
Reporting Intervals: Daily, Hourly, 15 minute
Precipitation
Variable or Sensor: TE525-L25 tipping bucket rain guage
Height of Sensor: 19 feet
Sensor Setup: on telephone pole above grape canopy
When Installed: 10 April 1997
Reporting Intervals: Daily, Hourly, 15 minute
Relative Humidity, max/min
Variable or Sensor: HMP45C-L5 temp-rh probe
Height of Sensor: 5 feet
Sensor Setup: outside grape canopy
When Installed: 22 March 2002
Reporting Intervals: Daily
Relative Humidity, average
Variable or Sensor: HMP45C-L5 temp-rh probe
Height of Sensor: 5 feet
Sensor Setup: outside grape canopy
When Installed: 22 March 2002
Reporting Intervals: Daily, Hourly, 15 minute
Wind Sigma Theta
Variable or Sensor: Calculated from 3001 RM Young Wind Sentry Anemometer and Vane
Height of Sensor: 20 feet
Sensor Setup: above grape canopy
When Installed: 10 April 1997
Reporting Intervals: Daily, Hourly, 15 minute
Solar Radiation
Variable or Sensor: LiCor 200X Silicon pyranometer
Height of Sensor: 7 feet
Sensor Setup: above grape canopy
When Installed: 19 March 2002
Reporting Intervals: Daily, Hourly, 15 minute
Temperature Threshold Hours
Variable or Sensor: hours of T <= 32F; 70 <= T <= 85F; T > 95F
Sensor Setup: in grape canopy.
When Installed: 30 January 1998
Reporting Intervals: Daily
Wind Speed/Direction, average
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
Height of Sensor: 20 feet
Sensor Setup: above grape canopy.
When Installed: 10 April 1997
Reporting Intervals: Daily, Hourly, 15 minute
Wind Speed/Direction, maximum
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
Height of Sensor: 20 feet
Sensor Setup: above grape canopy.
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly, 15 minute

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: September 17, 2014 Contact webmaster.