|
|
How to Manage Pests
Description of Upper_Lake-02.P
(UPL)
|
PestCast Network(s)Lake County Pear, Lake County Pear and Grape
Observer
RACHEL ELKINS
Location
County: Lake
Nearest City: UPPER LAKE
Latitude: 39 deg
10 min N
Longitude: 122 deg
55 min W
Elevation: 1351 ft
Station and site characteristics
Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Pear
Ground cover: Pear orchard
Available data
UC IPM database records begin/end: March 19, 2009
/ on-going
Reporting interval: 15 minute, Hourly, Daily
Stored variables:
Air Temperature, max/min:
HMP45C-U-L80 temp-RH probe
Air Temperature 3, max/min:
HMP35LC-L8 temp-RH probe
Air Temperature, average:
HMP35C-U-L80 temp-RH probe
Air Temperature 3, average:
HMP35LC-L8 temp-RH probe
Chilling Hours:
hours T < 45F
Dew Point Temperature:
calculated from HMP35C temp-RH probe
Leaf wetness:
237-L80 resistance grid
Precipitation:
TE525-L25 tipping bucket rain guage
Relative Humidity, max/min:
HMP45C-U-L80 temp-RH probe
Relative Humidity 3, max/min:
HMP35C-U-L8 temp-RH probe
Relative Humidity, average:
HMP45C-U-L80 temp-RH probe
Relative Humidity 3, average:
HMP35C-U-L8 temp-RH probe
Wind Sigma Theta:
Calculated from 3001 RM Young Wind Sentry Anemometer and Vane
Temperature Threshold Hours:
hours of T <= 32F; 70 <= T <= 85F; T > 95F
Wind Speed/Direction, average:
3001 RM Young Wind Sentry Anemometer and Vane
Wind Speed/Direction, maximum:
3001 RM Young Wind Sentry Anemometer and Vane
Variables with computed averages: none
Details about reported variables
Air Temperature, max/min
| Variable or Sensor: |
HMP45C-U-L80 temp-RH probe |
| Height of Sensor: |
4 feet |
| Sensor Setup: |
in pear canopy |
| When Installed: |
18 March 2009 |
| Backup Station #1
/ #2
| UPPER_LAKE-01.P:AIR2 / LAKEPORT.T |
| Averages Station Backup: |
LAKEPORT.C |
| Reporting Intervals: |
Daily, Hourly |
Air Temperature 3, max/min
| Variable or Sensor: |
HMP35LC-L8 temp-RH probe |
| Height of Sensor: |
5 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Backup Station #1
| UPPER_LAKE-01.P:AIR |
| Averages Station Backup: |
LAKEPORT.C:AIR |
| Reporting Intervals: |
Daily |
Air Temperature, average
| Variable or Sensor: |
HMP35C-U-L80 temp-RH probe |
| Height of Sensor: |
4 feet |
| Sensor Setup: |
in pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Air Temperature 3, average
| Variable or Sensor: |
HMP35LC-L8 temp-RH probe |
| Height of Sensor: |
5 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, 15 minute |
Chilling Hours
| Variable or Sensor: |
hours T < 45F |
| Sensor Setup: |
in pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily |
Dew Point Temperature
| Variable or Sensor: |
calculated from HMP35C temp-RH probe |
| Sensor Setup: |
in canopy. |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Leaf wetness
| Variable or Sensor: |
237-L80 resistance grid |
| Height of Sensor: |
plant height |
| Sensor Setup: |
near station |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Precipitation
| Variable or Sensor: |
TE525-L25 tipping bucket rain guage |
| Height of Sensor: |
8 feet |
| Sensor Setup: |
outside pear and grape canopies |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly |
Relative Humidity, max/min
| Variable or Sensor: |
HMP45C-U-L80 temp-RH probe |
| Height of Sensor: |
4 feet |
| Sensor Setup: |
in pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily |
Relative Humidity 3, max/min
| Variable or Sensor: |
HMP35C-U-L8 temp-RH probe |
| Height of Sensor: |
5 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily |
Relative Humidity, average
| Variable or Sensor: |
HMP45C-U-L80 temp-RH probe |
| Height of Sensor: |
5 feet |
| Sensor Setup: |
in pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Relative Humidity 3, average
| Variable or Sensor: |
HMP35C-U-L8 temp-RH probe |
| Height of Sensor: |
5 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily |
Wind Sigma Theta
| Variable or Sensor: |
Calculated from 3001 RM Young Wind Sentry Anemometer and Vane |
| Height of Sensor: |
10 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Temperature Threshold Hours
| Variable or Sensor: |
hours of T <= 32F; 70 <= T <= 85F; T > 95F |
| Sensor Setup: |
in grape canopy. |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily |
Wind Speed/Direction, average
| Variable or Sensor: |
3001 RM Young Wind Sentry Anemometer and Vane |
| Height of Sensor: |
10 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Wind Speed/Direction, maximum
| Variable or Sensor: |
3001 RM Young Wind Sentry Anemometer and Vane |
| Height of Sensor: |
10 feet |
| Sensor Setup: |
outside pear canopy |
| When Installed: |
18 March 2009 |
| Comment: |
Located at the eastern edge of a pear orchard. |
| Reporting Intervals: |
Daily, Hourly, 15 minute |
Top of page
|