UC IPM Online UC ANR home page UC IPM home page

UC IPM Home

SKIP navigation

 

How to Manage Pests

California Weather Data: Station Description

Description of Black_Point.A (CIMIS #187, Black Point)

Network:

CIMIS — California Irrigation Management Information System

Observer

NORTH MARIN WATER DISTRICT - DWR CENTRAL DISTRICT

Location

South of Highway 37, East of 101
County: Marin    Nearest City: Novato
Latitude: 38 deg 05 min N    Longitude: 122 deg 32 min W    Elevation: 1 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Ground cover: Irrigated grass

Available data

UC IPM database records begin/end: September 27, 2003  /  on-going
Reporting interval: Daily
Stored variables:
Air Temperature, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Reference Evapotranspiration: Calculated from CIMIS hourly values.
Precipitation: Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Soil Temperature, max/min: Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction: Daily average measured at 2 m (6.5 ft).

Comments

Station is an ETo location. Station is located at the Novato Waste Water Treatment Plant.


Details about reported variables

Air Temperature, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 01 June 2003
Status: Active
Backup Station #1 / #2 PETALUMA_EAST.A   /  SNTAROSA.A
Averages Station Backup: NOVATO.A

98% of possible values are stored for the period 09/27/2003 to 12/18/2014.

Reference Evapotranspiration
Variable or Sensor: Calculated from CIMIS hourly values.

100% of possible values are stored for the period 09/27/2003 to 12/18/2014.

Precipitation
Variable or Sensor: Daily total measured in a 20 cm (8 in) diameter gauge.
Height of Sensor: 1 m (39 in)
When Installed: 01 June 2003
Status: Active
Backup Station #1 / #2 PETALUMA_EAST.A   /  OAKLAND_FOOTHILLS.A
Averages Station Backup: RICHMOND.C

98% of possible values are stored for the period 09/27/2003 to 12/18/2014.

Relative Humidity, max/min
Variable or Sensor: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 01 June 2003
Status: Active

98% of possible values are stored for the period 10/05/2003 to 12/18/2014.

Soil Temperature, max/min
Variable or Sensor: Daily max/min measured at a 15 cm (6 in) depth.
Height of Sensor: 15 cm (6 in) depth
When Installed: 01 June 2003
Status: Active
Backup Station #1 / #2 PETALUMA_EAST.A   /  SNTAROSA.A
Averages Station Backup: NOVATO.A

99% of possible values are stored for the period 09/27/2003 to 12/18/2014.

Solar Radiation
Variable or Sensor: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 01 June 2003
Status: Active
Backup Station #1 / #2 PETALUMA_EAST.A   /  OAKLAND_FOOTHILLS.A
Averages Station Backup: NOVATO.A

96% of possible values are stored for the period 09/27/2003 to 12/18/2014.

Wind Speed/Direction
Variable or Sensor: Daily average measured at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 01 June 2003
Status: Active

96% of possible values are stored for the period 10/05/2003 to 12/18/2014.

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: December 20, 2014 Contact webmaster.