How to Manage Pests
Description of Delta-01.P
(CTR1)
|
PestCast Network(s)2008 California Tomato
Observer
CTRI
Location
Near South MacArthur Drive and West Delta Avenue
County: San Joaquin
Nearest City: Stockton
Latitude: 37 deg
48 min N
Longitude: 121 deg
25 min W
Elevation: 7 ft
Station and site characteristics
Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Processing tomatoes
Available data
UC IPM database records begin/end: June 24, 2008
/ September 18, 2008
Reporting interval: 30 minute, Hourly, Daily
Stored variables:
Air Temperature, max/min:
HMP35/45C temp-RH probe
Air Temperature 2, max/min:
HMP35/45C temp-RH probe
Air Temperature, average:
HMP35/45C temp-RH probe
Air Temperature 2, average:
HMP35/45C temp-RH probe
Growing Degree Days:
Calculated degree-days (thresholds: 41 F, 97 F) from air temps
Growing Degree Days 2:
Calculated degree-days (thresholds: 41 F, 97 F) from air temps
Temperature Threshold Hours:
Hours between 65 F and 75 F with RH > 90%
Temperature Threshold Hours 2:
Hours between 65 F and 75 F with RH > 90%
Leaf wetness:
237 resistance grid
Leaf wetness 2:
237 resistance grid
Relative Humidity, max/min:
HMP35/45C temp-RH probe
Relative Humidity 2, max/min:
HMP35/45C temp-RH probe
Relative Humidity, average:
HMP35/45C temp-RH probe
Relative Humidity 2, average:
HMP35/45C temp-RH probe
TomCast DSV:
Calculated TOM-CAST DSV from leaf wetness and air temp
TomCast DSV 2:
Calculated TOM-CAST DSV from leaf wetness and air temp
Variables with computed averages: none
Details about reported variables
Air Temperature, max/min
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Height of Sensor: |
plant height |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Daily, Hourly |
Air Temperature 2, max/min
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Height of Sensor: |
plant height |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Daily, Hourly |
Air Temperature, average
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Height of Sensor: |
plant height |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Daily, Hourly, 30 minute |
Air Temperature 2, average
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Height of Sensor: |
plant height |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Daily, Hourly, 30 minute |
Growing Degree Days
| Variable or Sensor: |
Calculated degree-days (thresholds: 41 F, 97 F) from air temps |
| Sensor Setup: |
in canopy |
| Reporting Intervals: |
Daily |
Growing Degree Days 2
| Variable or Sensor: |
Calculated degree-days (thresholds: 41 F, 97 F) from air temps |
| Sensor Setup: |
in canopy |
| Reporting Intervals: |
Daily |
Temperature Threshold Hours
| Variable or Sensor: |
Hours between 65 F and 75 F with RH > 90% |
| Sensor Setup: |
in canopy |
| Reporting Intervals: |
Daily |
Temperature Threshold Hours 2
| Variable or Sensor: |
Hours between 65 F and 75 F with RH > 90% |
| Sensor Setup: |
in canopy |
| Reporting Intervals: |
Daily |
Leaf wetness
| Variable or Sensor: |
237 resistance grid |
| Height of Sensor: |
plant height |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Reporting Intervals: |
Daily, Hourly, 30 minute |
Leaf wetness 2
| Variable or Sensor: |
237 resistance grid |
| Height of Sensor: |
plant height |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Reporting Intervals: |
Daily, Hourly, 30 minute |
Relative Humidity, max/min
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Hourly, Daily |
Relative Humidity 2, max/min
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Hourly |
Relative Humidity, average
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Daily, Hourly, 30 minute |
Relative Humidity 2, average
| Variable or Sensor: |
HMP35/45C temp-RH probe |
| Sensor Setup: |
in canopy |
| When Installed: |
23 June 2008 |
| Comment: |
Location is in tomato field. |
| Reporting Intervals: |
Daily, Hourly, 30 minute |
TomCast DSV
| Variable or Sensor: |
Calculated TOM-CAST DSV from leaf wetness and air temp |
| Sensor Setup: |
in canopy |
| Reporting Intervals: |
Daily |
TomCast DSV 2
| Variable or Sensor: |
Calculated TOM-CAST DSV from leaf wetness and air temp |
| Sensor Setup: |
in canopy |
| Reporting Intervals: |
Daily |
Top of page
|