How to Manage Pests
Description of Nickels_Soils_Lab.P
(NSL, Arbuckle/Nickels Soils Lab)
|
PestCast Network(s)Independent
Observer
John Edstrom
Location
Green Bay Road and California Avenue, 3 miles SE of Arbuckle
County: Colusa
Nearest City: Arbuckle
Latitude: 38 deg
58 min N
Longitude: 122 deg
05 min W
Elevation: 160 ft
Station and site characteristics
Manufacturer/model: Campbell Scientific CR10X
Ground cover: Clean,
Soil type: Sandy Loam
Available data
UC IPM database records begin/end: February 10, 2001
/ on-going
Reporting interval: Hourly, Daily
Stored variables:
Air Temperature, max/min:
Rotronics HP-043 Probe
Air Temperature, average:
Rotronics HP-03 probe
Bee Flight Time:
calculated using air temp sensor
Dew Point Temperature:
calculated from HP-043 probe
Evapotranspiration:
Calculated Reference Evapotranspiration
Precipitation:
TR-525WSW tipping bucket rain gauge
Relative Humidity, max/min:
Rotronics HP-043 probe
Relative Humidity, average:
Rotronics HP-043 probe
Solar Radiation:
Li200X Silicon pyranometer
Air Temp Thresholds:
hours of T <= 32F; T <= 28F; T <= 26F
Wind Speed/Direction, average:
Wind Sentry Wind Speed/Direction Sensor
Wind Speed/Direction, maximum:
Wind Sentry Wind Direction Sensor
Variables with computed averages: none
Comments
Open area 150 feet away from buidling and 50 feet away from trees.
Details about reported variables
Air Temperature, max/min
| Variable or Sensor: |
Rotronics HP-043 Probe |
| Height of Sensor: |
5 feet |
| When Installed: |
08 February 2001 |
| Status: |
Active |
| Backup Station #1
| ZAMORA.A |
| Averages Station Backup: |
ZAMORA.A |
| Comment: |
Location is in an almond field. |
| Reporting Intervals: |
Daily |
Air Temperature, average
| Variable or Sensor: |
Rotronics HP-03 probe |
| Height of Sensor: |
5 feet |
| When Installed: |
08 February 2001 |
| Status: |
Active |
| Reporting Intervals: |
Daily, Hourly |
Bee Flight Time
| Variable or Sensor: |
calculated using air temp sensor |
| When Installed: |
10 February 2001 |
| Reporting Intervals: |
Daily |
Dew Point Temperature
| Variable or Sensor: |
calculated from HP-043 probe |
| When Installed: |
08 February 2001 |
| Status: |
Active |
| Reporting Intervals: |
Daily, Hourly |
Evapotranspiration
| Variable or Sensor: |
Calculated Reference Evapotranspiration |
| Sensor Setup: |
calculated |
| When Installed: |
01 February 2001 |
| Comment: |
Per John Edstrom, ET resumed (7/28/05) |
| Reporting Intervals: |
Daily |
Precipitation
| Variable or Sensor: |
TR-525WSW tipping bucket rain gauge |
| Height of Sensor: |
3 feet |
| When Installed: |
08 February 2001 |
| Status: |
Active |
| Reporting Intervals: |
Daily, Hourly |
Relative Humidity, max/min
| Variable or Sensor: |
Rotronics HP-043 probe |
| Height of Sensor: |
5 feet |
| When Installed: |
08 February 2001 |
| Status: |
Active |
| Reporting Intervals: |
Daily |
Relative Humidity, average
| Variable or Sensor: |
Rotronics HP-043 probe |
| Height of Sensor: |
5 feet |
| When Installed: |
08 February 2001 |
| Status: |
Active |
| Reporting Intervals: |
Daily, Hourly |
Solar Radiation
| Variable or Sensor: |
Li200X Silicon pyranometer |
| Height of Sensor: |
6 feet |
| When Installed: |
23 February 2001 |
| Reporting Intervals: |
Daily, Hourly |
Air Temp Thresholds
| Variable or Sensor: |
hours of T <= 32F; T <= 28F; T <= 26F |
| When Installed: |
10 February 2001 |
| Reporting Intervals: |
Daily |
Wind Speed/Direction, average
| Variable or Sensor: |
Wind Sentry Wind Speed/Direction Sensor |
| Height of Sensor: |
5 |
| When Installed: |
08 February 2001 |
| Reporting Intervals: |
Hourly |
Wind Speed/Direction, maximum
| Variable or Sensor: |
Wind Sentry Wind Direction Sensor |
| Height of Sensor: |
10 feet |
| When Installed: |
08 February 2001 |
| Reporting Intervals: |
Daily, Hourly |
Top of page
|