UC IPM Online UC ANR home page UC IPM home page

UC IPM Home

SKIP navigation

 

How to Manage Pests

California Weather Data: Station Description

Description of OXNARD.A (CIMIS #156, Oxnard)

Network:

CIMIS — California Irrigation Management Information System

Observer

DWR - SOUTHERN DISTRICT

Location

River Ridge Golf Course
County: Ventura    Nearest City: Oxnard
Latitude: 34 deg 14 min N    Longitude: 119 deg 12 min W    Elevation: 48 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Ground cover: Irrigated Turf, Soil type: Sandy Loam

Available data

UC IPM database records begin/end: October 12, 2001  /  on-going
Reporting interval: Daily
Stored variables:
Air Temperature, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Evapotranspiration: Calculated from CIMIS hourly values.
Precipitation: Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Soil Temperature, max/min: Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction, average: Daily average measured at 2 m (6.5 ft).
Variables with computed averages: precip, air temp, soil temp, solar


Details about reported variables

Air Temperature, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 12 October 2001
Status: Acive
Backup Station #1 / #2 CAMARILLO.A   /  OXNARD.C
Averages Station Backup: OXNARD.C

98% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Evapotranspiration
Variable or Sensor: Calculated from CIMIS hourly values.

100% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Precipitation
Variable or Sensor: Daily total measured in a 20 cm (8 in) diameter gauge.
Height of Sensor: 1 m (39 in)
When Installed: 12 October 2001
Status: Active
Backup Station #1 / #2 CAMARILLO.A   /  OXNARD.C
Averages Station Backup: OXNARD.C

99% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Relative Humidity, max/min
Variable or Sensor: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 12 October 2001
Status: Active

98% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Soil Temperature, max/min
Variable or Sensor: Daily max/min measured at a 15 cm (6 in) depth.
Height of Sensor: 15 cm (6 in) depth
When Installed: 12 October 2001
Status: Active
Backup Station #1 CAMARILLO.A

99% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Solar Radiation
Variable or Sensor: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 12 October 2001
Status: Active
Backup Station #1 CAMARILLO.A
Averages Station Backup: PIRU.A

94% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Wind Speed/Direction, average
Variable or Sensor: Daily average measured at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 12 October 2001
Status: Active

100% of possible values are stored for the period 12/09/2001 to 07/23/2014.

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: July 25, 2014 Contact webmaster.