Description of SAND_RANCH-01.P (SR1)

PestCast Network(s)

Fresno-Madera Grape, Fresno County Grape

Observer

Kip Green

Location

Approx. 2.5 miles SE of Manning/McMullen Grade.
County: Fresno    Nearest City: Fresno
Latitude: 36 deg 32 min N    Longitude: 120 deg 02 min W    Elevation: 193 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific CR10X
Crop: Grape

Available data

UC IPM database records begin/end: April 10, 2002  /  on-going
Reporting interval: Hourly, Daily
Stored variables:
Air Temperature, max/min: HMP45C-U temp-RH probe
Air Temperature 2, max/min: 107-L150
Air Temperature, average: HMP45C-U temp-RH probe
Air Temperature 2, average: 107-U thermistor
Chilling Hours: hours T < 45F
Precipitation: TE525-L25 tipping bucket rain guage
Relative Humidity, max/min: HMP45C-U w/ 9ft cable
Relative Humidity, average: HMP45C-U temp-RH probe
Wind Sigma Theta: Calculated from 3001 RM Young Wind Sentry Anemometer and Vane
Temperature Threshold Hours: hours of T <= 32F; 70 <= T <= 85F; T > 95F
Wind Speed/Direction, average: 3001 RM Young Wind Sentry Anemometer and Vane
Wind Speed/Direction, average: 3001 RM Young Wind Sentry Anemometer and Vane
Wind Speed/Direction, maximum: 3001 RM Young Wind Sentry Anemometer and Vane
Variables with computed averages: none


Details about reported variables

Air Temperature, max/min
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: above the canopy
When Installed: 11 April 2002
Backup Station #1 / #2 CARUTHERS-01.P   /  FIVE_PTS.A
Averages Station Backup: FIVE_PTS.C
Reporting Intervals: Daily, Hourly
Air Temperature 2, max/min
Variable or Sensor: 107-L150
Sensor Setup: inside the canopy with no other significant obstructions
When Installed: 11 April 2002
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Air Temperature, average
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: above the canopy
When Installed: 11 April 2002
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Air Temperature 2, average
Variable or Sensor: 107-U thermistor
Sensor Setup: above the canopy with no significant obstructions.
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Hourly
Chilling Hours
Variable or Sensor: hours T < 45F
When Installed: 11 April 2002
Reporting Intervals: Daily
Precipitation
Variable or Sensor: TE525-L25 tipping bucket rain guage
Sensor Setup: Above the canopy with no significant obstructions.
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Relative Humidity, max/min
Variable or Sensor: HMP45C-U w/ 9ft cable
Sensor Setup: above the canopy
When Installed: 11 April 2002
Comment: Location is surrounded by tomato fields.
Reporting Intervals: Daily, Hourly
Relative Humidity, average
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: above the canopy
When Installed: 11 April 2002
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Wind Sigma Theta
Variable or Sensor: Calculated from 3001 RM Young Wind Sentry Anemometer and Vane
Height of Sensor: 10 feet
Sensor Setup: outside grape canopy
When Installed: 11 April 2002
Reporting Intervals: Daily, Hourly, 15 minute
Temperature Threshold Hours
Variable or Sensor: hours of T <= 32F; 70 <= T <= 85F; T > 95F
When Installed: 30 January 1998
Reporting Intervals: Daily
Wind Speed/Direction, average
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
Sensor Setup: Above the canopy with no significant obstructions.
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Wind Speed/Direction, average
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
Sensor Setup: Above the canopy with no significant obstructions.
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Wind Speed/Direction, maximum
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
Sensor Setup: Above the canopy with no significant obstructions.
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: October 23, 2014 Contact webmaster.