Description of STAPAULA.A (CIMIS #58, Santa Paula)

Network:

CIMIS — California Irrigation Management Information System

Observer

DWR - SOUTHERN DISTRICT

Location

County: Ventura    Nearest City: Santa Paula
Latitude: 34 deg 18 min N    Longitude: 119 deg 7 min W    Elevation: 175 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Ground cover: Irrigated grass

Available data

UC IPM database records begin/end: July 30, 1987  /  February 15, 1991
Reporting interval: Daily
Stored variables:
Air Temperature, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Reference Evapotranspiration: Calculated from CIMIS hourly values.
Precipitation: Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Soil Temperature, max/min: Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction: Daily average measured at 2 m (6.5 ft).
Variables with computed averages: none


Details about reported variables

Air Temperature, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
Backup Station #1 / #2 CAMARILLO.A   /  STAPAULA.C
Averages Station Backup: STAPAULA.C

98% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Reference Evapotranspiration
Variable or Sensor: Calculated from CIMIS hourly values.

100% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Precipitation
Variable or Sensor: Daily total measured in a 20 cm (8 in) diameter gauge.
Backup Station #1 / #2 CAMARILLO.A   /  STAPAULA.C
Averages Station Backup: STAPAULA.C

97% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Relative Humidity, max/min
Variable or Sensor: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)

100% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Soil Temperature, max/min
Variable or Sensor: Daily max/min measured at a 15 cm (6 in) depth.
Height of Sensor: 15 cm (6 in) depth
Backup Station #1 CAMARILLO.A
Averages Station Backup: PIRU.A

100% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Solar Radiation
Variable or Sensor: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
Backup Station #1 CAMARILLO.A
Averages Station Backup: PIRU.A

99% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Wind Speed/Direction
Variable or Sensor: Daily average measured at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)

99% of possible values are stored for the period 07/30/1987 to 02/14/1991.

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: August 23, 2014 Contact webmaster.