UC IPM Online UC ANR home page UC IPM home page

UC IPM Home

SKIP navigation

 

How to Manage Pests

California Weather Data: Station Description

Description of Westmorland_North.A (CIMIS #181, Westmorland North)

Network:

CIMIS — California Irrigation Management Information System

Observer

Imperial Irrigation District

Location

1-1/2 miles North an West of Westmorland
County: Imperial    Nearest City: Westmorland
Latitude: 33 deg 05 min N    Longitude: 115 deg 40 min W    Elevation: -200 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific CR10 or CR10X
Ground cover: Alfalfa, Soil type: Clay Loam

Available data

UC IPM database records begin/end: April 1, 2004  /  on-going
Reporting interval: Daily
Stored variables:
Air Temperature, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Reference Evapotranspiration: Calculated from CIMIS hourly values.
Precipitation: Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Soil Temperature, max/min: Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction: Daily average measured at 2 m (6.5 ft).
Variables with computed averages: none

Comments

Station is relocation of CIMIS Station 180, Westmorland West. Site is flood irrigated. Station removed from service 6/17/2009. Returned to service 11/26/2009.


Details about reported variables

Air Temperature, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 01 April 2004
Status: Active
Backup Station #1 / #2 BRAWLEY.A   /  SALTNCTY.A
Averages Station Backup: BRAWLEY.C

95% of possible values are stored for the period 04/01/2004 to 07/31/2015.

Reference Evapotranspiration
Variable or Sensor: Calculated from CIMIS hourly values.

100% of possible values are stored for the period 04/01/2004 to 07/31/2015.

Precipitation
Variable or Sensor: Daily total measured in a 20 cm (8 in) diameter gauge.
Height of Sensor: 1 m (39 in)
When Installed: 01 April 2004
Status: Active
Backup Station #1 / #2 BRAWLEY.A   /  BRAWLEY.T
Averages Station Backup: BRAWLEY.C

100% of possible values are stored for the period 04/01/2004 to 07/31/2015.

Relative Humidity, max/min
Variable or Sensor: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 01 April 2004
Status: Active

95% of possible values are stored for the period 04/01/2004 to 07/31/2015.

Soil Temperature, max/min
Variable or Sensor: Daily max/min measured at a 15 cm (6 in) depth.
Height of Sensor: 15 cm (6 in) depth
When Installed: 01 April 2004
Status: Active
Backup Station #1 / #2 BRAWLEY.A   /  ELCENTRO.A
Averages Station Backup: BRAWLEY.A

95% of possible values are stored for the period 04/01/2004 to 07/31/2015.

Solar Radiation
Variable or Sensor: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 01 April 2004
Status: Active
Backup Station #1 / #2 BRAWLEY.A   /  SALTNCTY.A
Averages Station Backup: BRAWLEY.A

93% of possible values are stored for the period 04/01/2004 to 07/31/2015.

Wind Speed/Direction
Variable or Sensor: Daily average measured at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 01 April 2004
Status: Active

97% of possible values are stored for the period 04/26/2004 to 07/31/2015.

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2015 The Regents of the University of California. All rights reserved.

web template revised: August 2, 2015 Contact webmaster.